than five feet from the side lot line provided such structures, except for swimming Any subsequent construction or alteration that extends an existing mobile home park No. 4 photographs attached to Pre-House Moving Application; tax parcel # & address where structure is now; tax parcel # & address of new location; Historical approval will look at age of structure and historical concerns about relocationOWNERS CANNOT ACT AS THE CONTRACTOR. 2 copies scope of work list; 2 copies floor plan (Existing and proposed) if part or all of project more closely resembles "Alteration" or "Addition", see those work types for possible requirement of engineered plans, etc. Burglar alarm/ security systems (low voltage systems), low voltage alarms that can be plugged into an existing outlet, do not need a permit. SINGLE-FAMILY DWELLING REQUIREMENTS ZONING CLASSIFICATION FR RC A-1 A-2 A-3 A-4 RA RR RE Minimum Lot Size 20 acres 25 acres 10 acres 5 acres 1 acre 2.5 acres 2.5 acres 1 acre 2.5 acres Minimum Lot Width 150 ft. 150 ft. 150 ft. 150 ft. 150 ft. 150 ft. 150 ft. 100 ft. 100 ft. . Principle building setbacks vary by zoning district. All bulkheads, seawalls, retaining walls, docks, wharfs, piers, floating docks, boat Single-Family Residential Zone Regulations Page 2 . %%EOF 2 sets of construction plans with the architect's / engineer's seal; 1 survey with the surveyor's seal; 2 site plans; septic location; if alum construction, see "Addition (Alum)". Contact us at No. 2004-20, the distance between the front lines and the fronts of the principal buildings on There is no setback required for a fence. **THESE PERMITS NEED TO GO THROUGH LAND DEVELOPMENT PRIOR TO SUBMITTAL FOR BUILDING PERMITS** Refer to "Single Family Residence" requirements. The structure may not have more than 750square feet of area, excluding walkway extensions, and shall not be higher than 15 feet above the mean high water mark. accordance with the National Electric Code, may approve additional service size. The cumulative area of all accessory buildings or structures, excluding docks, seawalls, Fence (non-structural and structural without footers) (Owner/renter contractor). Fort Walton Beach, FL . Can I put a storage shed on the vacant lot? specifications on generator & transfer switch must be on the jobsite for inspection; (if electric only for future generator, see the instructions for electrical for generator/transfer switch instead); 2 site plans; septic waiver if septic tank and drainfield located in same area of the yard as the proposed generator; septic location; name electric subcontractor; ** if generator is existing and this is a change out, only an electrical permit is required. Under certain circumstances, a garage apartment may be built on your lot. Master plans are not accepted in place of these requirements. We create plans and other documentation necessary to bring your building into compliance with local building codes. On any lot with 50 feet or less of depth and at least 5,000 square feet of area, that Can I put a carport in front of my garage? Q. Notwithstanding the dimensional requirements set forth in section 72-241, conservation subdivisions may be developed in any zoning classification pursuant 3. the following requirements shall apply: Said cabins shall contain no plumbing, cooking Phone This is accomplished through our Land Development Office and may also involve vacating any easements that may be between the lots. but they shall not be located in platted easements. All rights reserved. The chimneys, fireplaces, roof overhangs, unenclosed balconies and unenclosed stairways to section 72-547 and the following: (Ord. ** (ex. In agricultural zones, setbacks are the same for all structures except those erected to protect fern or other agricultural crops. In general, fences in residentially zoned areas, cannot exceed six feet along the rear and side lot lines of an interior lot and four feet along a front lot line. shall comply with the provisions of these regulations, including those provisions Docks and boathouses are permitted on waterfront property, provided there is a principal building on the lot. An accessory structure shall not be separately metered for electricity over 60 amperes A building setback is the required distance that a building must be located from the property lines. No. 2015-02 five percent of the total land area of the project. the adjacent properties. This subsection shall not apply to lots of one acre No. located on waterfront lots shall be set back ten feet from the waterfront lot line. Home-based business (refer to section 72-283). 2 sets of construction plans with the architect's / engineer's seal if change is structural or affects the building envelope (Ex: convert garage to living area) or 2 copies scope of work list; 2 truss packets with the engineer's seal if applicable; 1 survey with the surveyor's seal and 2 site plans if changing footprint of building; floor plan showing location of work; septic waiver/location if applicable; energy forms if change to habitable area. 90-34, 49, 50, 9-27-90; Ord. High risk flood zones include A, AE, AO, V, and VE. structures may be located in rear or side yards not less than five feet from the lot How am I able to tell if my address is within Ormond Beach jurisdiction or Volusia County? Q. I want to put a storage shed in my back yard. 86-16, XIV, XV, 10-23-86; Ord. 35 0 obj <> endobj point of the principal structure. Web Design by DigitalUs on Solodev, We use cookies to provide and improve our services. Q. 88-2, VIII, 1-19-88; Ord. What is a Comprehensive Plan versus the Land Development Code? ** (ex. Q. SECTION 810.04 DOES NOT PERMIT REQUIRED OFF STREET PARKING SPACES TO BE LOCATED IN ANY PLATTED EASEMENTS. for its classification, its minimum front yard requirement shall be the average of 2015-02 Your legal right to trim branches hanging over your property line will depend on the health of the tree. In all zoning classifications, off-street parking lots may be in yards to the extent Sheds need to be anchored to the ground for wind resistance. The Form Based Code consists of a set of regulations developed to implement the Downtown Master Plan in order to encourage and facilitate redevelopment in the downtown area. hTj@yl)$`'QRP,iSv$!arfV1pP $"C!E=A k4C'']d8EFIxu7K}tQFtIme7t\brilIYtZ?D(0)GS.OS,-HMn?wT#Yci:Bi'e._Y7g"TK,Y4BSl\)XU^/jjRNu+4"^M;nn$r C_i}X/8q'{{p these regulations, the average setback actually observed shall apply to all new construction 2 sets of construction plans with the architect's / engineer's seal or 2 sets of current master plan engineering with Aluminum Framing Plan and copy of engineers authorization letter if change is structural or affects the building envelope; 1 survey with the surveyor's seal and 2 site plans if changing footprint of building; floor plan showing location of work; septic location; energy forms if heating or cooling project area. Only one structure over 500 square feet in area shall be allowed in an urban residential classification. Can I build a dock and boathouse? pools, are not located in the side yard area between the rear lot line and the rearmost issued prior to commencement of construction. In residential zoning, can I build a garage or storage shed before I build my house? > Can I put a mobile home on my property? Q. Q. Q. There shall be at least one active recreational area. f. Siding/soffit/fascia (tear off and install). The zoning districts are utilized to promote land use compatibility as a means of protecting the health, safety and general welfare of the City and its citizens. A permit is not required for small manufactured sheds (storage/utility) under 50 square feet (5 x 10) in area, with no permanent base/slab. Other areas permit not required but must refer to Zoning for setback and wetland issues. ); 2 copies of floor plan showing any improvements (**additional plans or scope of work list if alterations or repairs); proof of water (most current utility bill); septic permit or proof of sewer; energy forms. All mobile home and recreational vehicle parks shall comply with the Land Development ZONING: Division 8. The fence must be placed on the inside of your property line. Zoning determines eligibility, must have existing agricultural exemption on tax bill use application available from Zoning call 386-943-7059. Protected trees may be removed with proper permitting, but require replacement. ***NO POOL SUBMITTALS ALLOWED WITHOUT SAFETY FEATURE ***, Townhouse (separate parcels separate permits owner contractor allowed for the parcel where he/she will reside.). 2 sets of of plans with the architect's / engineer's seal or 2 copies of full size copies DCA approved plans; if anchoring is not shown on plans need engineered anchoring plan; 1 survey with the surveyor's seal; 2 site plans; septic location. These regulations shall be known and may be cited as the "Zoning Ordinance of Volusia County, Florida." (Ord. and structures; The proposed single-family residence is to be connected to central water and sewer No. DeLand, FL 32720 By using our site, you consent to cookies. Those exceptions permitted in section 72-290 pertaining to automobile service stations. The pool or other accessory structure setbacks are usually less than the required principal structure setbacks but these accessory structures can only be located in rear or side yards, not in the required front yard area. A final site plan development order for new parks and expansion of existing parks, Stucco over frame: 2 copies of wall section (engineers seal not required). No. DeLand, FL 32720 , III, 3-5-15; Ord. 2004-20, No accessory structures shall be permitted on any recreational vehicle park space 1-20-11; Ord. Landscaped buffer areas meeting the requirements of section 72-284 shall be constructed. Phase II, are being proposed to ensure proper regulation for the implementation of potable reuse programs in the state of Florida. On residential lots, trees over 6 inches in diameter at breast height (DBH) in the zoning setbacks are considered protected. 2 sets of construction plans with the architect's / engineer's seal or 2 sets of current master plan engineering with Aluminum Framing Plan (including 4th wall construction) and copy of engineers authorization letter; 1 survey with the surveyor's seal & 2 site plans or if inside a mobile home park, 2 site plans only; septic location. 2 sets of construction plans with the architect's / engineer's seal; 2 truss packets with the engineer's seal; 1 survey with the surveyor's seal; 2 site plans; septic waiver; energy forms. A pre-application meeting with a planner is the next step in the process. Maximum 600 lots. Pull Pre-House Moving paperwork & put with this permit; 1 survey with the surveyor's seal; 2 site plans minimum (more if driveway, tree, etc. No. Awnings may project into any yard for either 3 feet or half of the yard, whichever 2 sets of construction plans (plans will need architect's / engineer's seal if it is covered) 3rd set for Wetlands (do not need the architect's / engineer's seal); 1 survey with the surveyor's seal; 3 site plans; select 'Wetland Alteration' as additional work type. 88-2, X, 1-19-88; Ord. for any sale of the mobile homes in the park, construction of the required improvements 2008-25, II, 12-4-08; Ord. An accessory structure shall not be separately metered for electricity over 60 amperes For further information, please contact one of our offices: 1804 Lewis Turner Blvd . 1. 46/246 : Proposed c. No minimum lot size. However, accessory If, because of prior zoning regulations, or because of a unified plan of development, DeLand, FL 32720 Shed (wood/masonry) - larger than 10 x 12. 92-6, XLVII, 6-4-92; Ord. or attached to any mobile recreational shelter or vehicle. Every zoning classification requires a minimum lot size. In addition, the Ordinance is accessible on the internet at http://www.municode.com. endstream endobj startxref hbbd``b`*@H0T&Fu YF? Park Model: See "Mobile Home" requirements RV Permanent Set Up (Zoning will only allow RVs in areas zoned for RV Parks) similar to "Mobile Home" requirements, but no set up book (need 2 copies of manufacturer's tie down information); 1 survey with the surveyor's seal; 2 site plans or if inside a park, 2 site plans only; Proof of Water; septic permit or Proof of Sewer; No energy forms needed for RVs. 90-34, 49, 50, 9-27-90; Ord. In Brevard County, 440 residential condominiums are 40 years of age or older, with more than 100 constructed in the 1950s and 1960s, county property records show. Individuals can also sign up at:https://www.ormondbeach.org/list.aspx for news and notices to be provided by e-mail. The land use designation defines broad uses, density, and intensity and the zoning provides specific development and use standards. No. By using our site, you consent to cookies. Volusia County Property Appraiser's Office (vcgov.org). It is possible in some cases to re-subdivide the property and build a separate home on the new lot, but, as a rule, only one single family home may be built on a parcel of property. Code Violation issues can be problematic but IPC . Fire stations. For more information, please click on the following link: https://www.ormondbeach.org/243/Floodplain-Management. Typically, a storage shed must be located a minimum distance of five feet from the property line. Submittal Requirements Checklist: Per the Florida Building Code, sheds 200 square feet or less and used exclusively for storage purposes are exempt from permitting requirements. plants are exempt from the maximum lot coverage requirements in MH-3 and in all of However, in residential classifications the cumulative square footage for accessory structures cannot exceed 50% of the principal structure square footage. spaces or streets which do not increase their nonconformity shall be permitted. Q. 120 Gallon Underground Propane Tank 30" Deep 30" Wide 6' Long 250 Gallon Underground Propane Tank 4' Deep 4' Wide 8' Long Standard ASME Propane Tank Specifications A+ Better Business Rated Switch today and save up to 50% Off Call Now for an Instant Phone Quote 1 (877) 658-5527 specifications on generator & transfer switch must be on the jobsite for inspection; (if electric only for future generator, see the instructions for electrical for generator/transfer switch instead); 2 site plans; septic waiver if septic tank and drainfield located in same area of the yard as the proposed generator; septic location. Entrances and exits shall be limited in number and when combined, shall be separated (386) 736-2700, 123 W. Indiana Ave shall meet the same yard requirements as the principal building. Only certain zoning classifications allow mobile homes. accessory structures to the main use or structures of the premises. In general, fences in residentially zoned areas, cannot exceed six feet along the rear and side lot lines of an interior lot and four feet along a front lot line. these regulations, the average setback actually observed shall apply to all new construction 94-4, XLIXLII, 5-5-94; Ord. %PDF-1.5 % The Land Development Code provides detail regulations such as zoning uses, dimensional standard, conditions for uses, parking requirements, landscape and tree preservation standards, architectural regulations, and environmental standards. or water. While most of those older . 87-14, XV, 6-18-87; Ord. 2 sets construction plans (if being used as a retaining wall, see that category for plan requirements); 1 survey with the surveyor's seal; 2 site plans; septic location. No. lines or in platted easements. No. (6) Site-built cabins: One unit per 20 recreational vehicle or campsite spaces. Q. shall not be located in any yard abutting a street but may be located not less than or greater in size. Additional requirements for recreational vehicle parks. No. (386) 736-2700, All Rights Reserved, 2023 Volusia County. 88-2, VIII, 1-19-88; Ord. In most residential areas, a carport may only be placed in front of a residence if it is attached to the residence, and meets the front yard building setback requirement for the area in which it is constructed. R101.2 Scope:Construction standards or practices which are not covered by this code shall be in accordance with the provisions of Florida Building Code, Building. into the water. How close to the property line can it be placed? the distance between the front lines and the fronts of the principal buildings on exempt from the yard requirements. 1 survey with the surveyor's seal; 2 site plans; septic location. Sheds greater than 50 square feet and less than 150 square feet and 10 or less in height require a building permit. Also, only one accessory structure over 500 square feet in area is allowed in an urban residential classifications. Building. 92-6, XLVII, 6-4-92; Ord. Transient lodging establishments in these zoning districts require a local business tax and must comply with all the state transient lodging regulations. Park trailers are permitted and must comply with F.S. residential neighborhood observe a setback greater than that which is required by over 500 square feet in area shall be allowed in an urban residential classification. Do I need a permit to replace my driveway? hTYo@+r v)d;q*T@akb`S%3Q[B b| "b -b47( d,="JxuPXH:dCJt7M%9[Gw?c N"s %\%[. The Ordinance, as amended is part of Chpater 72, Land Planning of the Volusia County Code of Ordinances, and it must be ordered from the Municipal Code Corporation, P.O. Multiple fixtures: 2 riser diagrams that include type of gas, pressure, piping material, pipe sizes, run lengths & BTU ratings of utilization equipment. No. Monday through Friday, 123 W. Indiana Ave. Tax District: 200 Unincorporated - Northeast is within Volusia County jurisdiction. Accept Learn more, Go To Social Media Page With Link To Facebook, Go To Social Media Page With Link To Twitter, Go To Social Media Page With Link To YouTube, Residential permit documentation requirements, Roundtable of Volusia County Elected Officials. Setbacks also vary by type of structure. How many horses are allowed per acre of land? In addition, 2006-18, 9-21-06; Ord. How can I get information on a project that will be heard by the Planning Board? b. This subsection shall not apply to lots of one acre 2 sets of construction plans with the architect's / engineer's seal; 1 survey with the surveyor's seal; 2 site plans; septic location; if there is an office in the hangar, see "Addition (Frame/Masonry) " work type.