Column 7 Lists the additional (special) provisions that apply to this material. Metal: 11A, 11B, 11N, 21A, 21B and 21N, b. B2 MC 300, MC 301, MC 302, MC 303, MC 305, and MC 306 and DOT 406 cargo tanks are not authorized. This document is available in the following developer friendly formats: Information and documentation can be found in our This may be fulfilled by an additional locking device linked to the activator; (4) Each article must be manufactured in such a way as to prevent hazardous projections of the pressure receptacle or parts of the pressure receptacle; (5) Each pressure receptacle must be manufactured from material which will not fragment upon rupture; (6) The design type of the article must be subjected to a fire test. N80 Packages consisting of one inner metal can, not over 2.5 kg (5.5 pounds) capacity, packed in an outer wooden or fiberboard box, or a wooden barrel, are authorized and need not conform to the requirements of part 178 of this subchapter. N20 A 5M1 multi-wall paper bag is authorized if transported in a closed transport vehicle. Test of type 3(c) is not required. TP5 For a portable tank used for the transport of flammable refrigerated liquefied gases or refrigerated liquefied oxygen, the maximum rate at which the portable tank may be filled must not exceed the liquid flow capacity of the primary pressure relief system rated at a pressure not exceeding 120 percent of the portable tank's design pressure. 16 This description applies to smokeless powder and other solid propellants that are used as powder for small arms and have been classed as Division 1.3C, 1.4C and Division 4.1 in accordance with 173.56 of this subchapter. For the regulatory description of the codes for special provisions, please refer to 49 CFR 172.102. 389 This entry only applies to lithium ion batteries or lithium metal batteries installed in a cargo transport unit and designed only to provide power external to the cargo transport unit. The means of protection must be approved by the approval agency designated to approve the portable tank in accordance with the procedures in part 107, subpart E, of this subchapter. Stacking is permitted two or more levels high to achieve maximum allowable utilization of the designated vehicle, rail car weight, or intermodal freight container weight or vessel hold volume. f. Flexible: 13H2, 13H3, 13H4, 13H5, 13L2, 13L3, 13L4, 13M1 and 13M2 (flexible IBCs must be sift-proof and water resistant or must be fitted with a sift-proof and water resistant liner). The chemical under pressure must be classed based on the hazard characteristics of the components in the propellant; the liquid; or the solid. For non-pressurized lighters containing a Class 3 (flammable liquid) material, its design, description, and packaging must be approved by the Associate Administrator prior to being offered for transportation or transported in commerce. 351 Ammonium chlorate, ammonium chlorate aqueous solutions, and mixtures of a chlorate with an ammonium salt are forbidden for transport. N76 For materials of not more than 25 percent active ingredient by weight, packages consisting of inner metal packagings not greater than 250 mL (8 ounces) capacity each, packed in strong outer packagings together with sufficient absorbent material to completely absorb the liquid contents are authorized and need not conform to the requirements of part 178 of this subchapter. 56 A means to interrupt and prevent detonation of the detonator from initiating the detonating cord must be installed between each electric detonator and the detonating cord ends of the jet perforating guns before the charged jet perforating guns are offered for transportation. If a package contains both lithium metal batteries and lithium ion batteries packed with and contained in equipment, then the shipping paper must indicate both UN 3091 Lithium metal batteries packed with equipment and UN 3481 Lithium ion batteries packed with equipment.. (iii) Constructing the battery with terminals that are recessed or otherwise protected so that the terminals will not be subjected to damage if the package is dropped. Where the subsidiary hazard material is Forbidden in column (9A) or (9B) of the 172.101 Table, the radioactive material may only be offered for transportation and transported by aircraft under conditions approved by the Associate Administrator. For transportation by passenger-carrying aircraft, the net mass of lighter refills may not exceed 1 kg per package, and, for cargo-only aircraft, the net mass of lighter refills may not exceed 15 kg per package. They must be classified in accordance with the procedure as set out in the Manual of Tests and Criteria, part III, section 39 (IBR, see 171.7 of this subchapter). 106 The recognized name of the particular explosive may be specified in addition to the type. 196 The nitrocellulose must meet the criteria of the Bergmann-Junk test or methyl violet paper test in the UN Manual of Tests and Criteria, Appendix 10 (IBR, see 171.7 of this subchapter). A copy of the approval must accompany each shipment. PDF 173.242 49 CFR Ch. I (10-1-04 Edition) - GovInfo 19 For domestic transportation only, the identification number UN1075 may be used in place of the identification number specified in column (4) of the 172.101 table. These provisions apply only to transportation in IBCs and Large Packagings. 165 These substances are susceptible to exothermic decomposition at elevated temperatures. 1/1.1 meet the venting requirements in 173.24(g) or (2.) It must not be used for machinery or apparatus for which a proper shipping name already exists in the 172.101 Table. Equipment powered by lithium metal batteries or lithium ion batteries must be described using the entries Lithium metal batteries contained in equipment or Lithium metal batteries packed with equipment or Lithium ion batteries contained in equipment or Lithium ion batteries packed with equipment, as appropriate. 65 The group of alkaline earth metals includes magnesium, calcium, strontium, and barium. Table 2 defines IP Codes on the use of IBCs that are assigned to specific commodities in the 172.101 Table of this subchapter. The table below gives the various types of Lead alloy solders. Pressure relief devices shall be designed to prevent the entry of foreign matter, the leakage of liquid and the development of any dangerous excess pressure. They must be classified in accordance with the procedure as set out in the Manual of Tests and Criteria, part III, section 39 (IBR, see 171.7 of this subchapter). Primary receptacles must conform to the general packaging requirements of subpart B of part 173 of this subchapter and may not leak. Bulk packagings must have exterior heating coils fusion welded to the tank shell which have been properly stress relieved. B133 Hydrochloric acid concentration not exceeding 38%, in Packing Group II, is authorized to be packaged in UN31H1 or UN31HH1 intermediate bulk containers when loaded in accordance with the requirements of 173.35(h) of this subchapter. B48 Portable tanks in sodium metal service may be visually inspected at least once every 5 years instead of being retested hydrostatically. Ch 6.0b Flashcards | Quizlet Choosing an item from For Federal Register citations affecting 172.102, see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume and at www.govinfo.gov. These packagings are not required to: (1.) A Shipper of a hazardous material is responsible for its classification and packaging prior to offering it for shipment to a Carrier. 54 Maneb or maneb preparations not meeting the definition of Division 4.3 or any other hazard class are not subject to the requirements of this subchapter when transported by motor vehicle, rail car, or aircraft. Solids meeting the definition of an elevated temperature material must be transported in accordance with the applicable requirements of this subchapter. If a package contains both lithium metal batteries and lithium ion batteries packed with and contained in equipment, the package must be marked as required for both battery types. 33 Ammonium nitrites and mixtures of an inorganic nitrite with an ammonium salt are prohibited. 140 This material is regulated only when it meets the defining criteria for a hazardous substance or a marine pollutant. Flexible, fiberboard or wooden IBCs must be sift-proof and water-resistant or be fitted with a sift-proof and water-resistant liner. A13 Bulk packagings are not authorized for transportation by aircraft. 167 These storage systems must always be considered as containing hydrogen. 49 Mixtures of solids that are not subject to this subchapter and corrosive liquids may be transported under this entry without first applying the classification criteria of Class 8, provided there is no free liquid visible at the time the material is loaded or at the time the packaging or transport unit is closed. If you have questions for the Agency that issued the current document please contact the agency directly. If it is evident that a package of radioactive material, or conveyance carrying unpackaged radioactive material, is leaking, or if it is suspected that the package, or conveyance carrying unpackaged material, may have leaked, the requirements of 173.443(e) of this subchapter apply. Each special provision is indicated using a numeric or alphanumeric code. 49 U.S.C. Model rocket motors containing 30 grams or less propellant are classed as Division 1.4S and items containing more than 30 grams of propellant but not more than 62.5 grams of propellant are classed as Division 1.4C. 139 Use of the special arrangement proper shipping names for international shipments must be made under an IAEA Certificate of Competent Authority issued by the Associate Administrator in accordance with the requirements in 173.471, 173.472, or 173.473 of this subchapter. A lighter refill exceeding 4 fluid ounces capacity (7.22 cubic inches) or containing more than 65 grams of fuel must be classed as a Division 2.1 material, described with the proper shipping name appropriate for the material, and packaged in the packaging specified in part 173 of this subchapter for the flammable gas contained therein. (4) IB Codes and IP Codes. c. A composite packaging 6PG2 (glass, porcelain or stoneware receptacles within a fiberboard box). Such articles must comply with the following requirements: (1) The water capacity of the pressure receptacle must not exceed 0.5 L and the working pressure must not exceed 25 bar at 15 C (59 F); (2) The minimum burst pressure of the pressure receptacle must be at least four times the pressure of the gas at 15 C (59 F); (3) Each article must be manufactured in such a way that unintentional firing or release is avoided under normal conditions of handling, packing, transport and use. 5101-5128, 44701; 49 CFR 1.81, 1.96 and 1.97. b. This provision may be used for both domestic and international shipments. N37 This material may be shipped in an integrally-lined fiber drum (1G) which meets the general packaging requirements of subpart B of part 173 of this subchapter, the requirements of part 178 of this subchapter at the packing group assigned for the material and to any other special provisions of column 7 of the 172.101 table. Tanks containing solidified methacrylic acid must not be reheated during transport. If you would like to comment on the current content, please use the 'Content Feedback' button below for instructions on contacting the issuing agency. Insulating materials must not promote corrosion to steel when wet. See UN1210, UN1263, UN1266, UN3066, UN3469, and UN3470. Ammonia solutions may be transported in rigid or composite plastic IBCs (31H1, 31H2 and 31HZ1) that have successfully passed, without leakage or permanent deformation, the hydrostatic test specified in. The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. Lead-free Solder Figure 3: Engineer soldering a microcircuit Note, Tin here is the primary metal. The guns are packaged in accordance with Packing Method US 1 as specified in 173.62 of this subchapter. This web site is designed for the current versions of Capacitors with an energy storage capacity of 0.3 Wh or less are not subject to the requirements of this subchapter. 175 This substance must be stabilized when in concentrations of not more than 99%. 352 Ammonium chlorite, ammonium chlorite aqueous solutions, and mixtures of a chlorite with an ammonium salt are forbidden for transport. 81 Polychlorinated biphenyl items, as defined in 40 CFR 761.3, for which specification packagings are impractical, may be packaged in non-specification packagings meeting the general packaging requirements of subparts A and B of part 173 of this subchapter. For continued use of approvals dated prior to January 1, 2012, see 173.308(b)(5). In addition, the portable tank must be designed so that internal surfaces may be effectively cleaned and passivated. View the most recent official publication: These links go to the official, published CFR, which is updated annually. The proper shipping name Paint related material, corrosive, flammable may be used for consignments of packages containing Paint, corrosive, flammable and Paint related material, corrosive, flammable in the same package; c. The proper shipping name Paint related material, flammable, corrosive may be used for consignments of packages containing Paint, flammable, corrosive and Paint related material, flammable, corrosive in the same package; and. (TOY CAPS) - HANDLE CAREFULLY OR TOY CAPS - HANDLE CAREFULLY; and. Subscribe to: Changes in Title 49 :: Subtitle B :: Chapter I :: Subchapter C :: Part 172 :: Subpart B :: Section 172.102. Individual Name: Mr. David Comen. These provisions can be classified even further with each form of transportation. Transportation of these packages also requires the door of each van trailer to be marked with Warning trailer may contain chemical vapor. Packaging must be UN standard metal drums attached with heavy duty steel strapping to a pallet; and. B131 When transported by highway, rail, or cargo vessel, waste Paint and Paint related material (UN1263; PG II and PG III), when in plastic or metal inner packagings of not more than 26.5 L (7 gallons), are excepted from the marking requirements in 172.301(a) and (c) and the labeling requirements in 172.400(a), when further packed in the following specification and non-specification bulk outer packagings and under the following conditions: a. 21 This material must be stabilized by appropriate means (e.g., addition of chemical inhibitor, purging to remove oxygen) to prevent dangerous polymerization (see 173.21(f) of this subchapter). N32 Aluminum materials of construction are not authorized for single packagings. TP38 Each portable tank must be insulated with an insulating material so that the overall thermal conductance at 15.5 C (60 F) is no more than 1.5333 kilojoules per hour per square meter per degree Celsius (0.075 Btu per hour per square foot per degree Fahrenheit) temperature differential. 391 Except for articles being transported by motor vehicle as a material of trade in accordance with 173.6 of this subchapter, articles containing hazardous materials of Division 2.3, or Division 4.2, or Division 4.3, or Division 5.1, or Division 5.2, or Division 6.1 (substances with an inhalation toxicity of Packing Group I) and articles containing more than one of the following hazards: (1) Gases of Class 2; (2) Liquid desensitized explosives of Class 3; or (3) Self-reactive substances and solid desensitized explosives of Division 4.1, may only be offered for transportation and transported under conditions approved by the Associate Administrator. All special provision B76 Tank cars constructed before March 16, 2009, must have a test pressure of 20.68 Bar (300 psig) or greater and conform to Class 105S, 112J, 114J or 120S. If a vehicle is powered by a flammable liquid and a flammable gas internal combustion engine, it must be described using Vehicle, flammable gas powered. This includes hybrid electric vehicles powered by both an internal combustion engine and wet, sodium or lithium batteries installed. This includes hybrid electric vehicles powered by a fuel cell, an internal combustion engine, and wet, sodium or lithium batteries installed. Wall thickness must be verified ultrasonically at intervals midway between periodic hydraulic tests (every 2.5 years). How to Use Hazmat Special Provisions | Lion Technology c. Completed neutron radiation detection systems containing detectors meeting the conditions of paragraph a of this special provision must be transported as follows: (1) The detectors must be contained in a strong sealed outer casing; (2) The casing must contain include sufficient absorbent or adsorbent material to absorb or adsorb the entire gas contents; (3) The completed system must be packed in strong outer packagings capable of withstanding a 1.8 meter (5.9 feet) drop test without leakage unless a system's outer casing affords equivalent protection. If chemical stabilization becomes ineffective at lower temperatures within the anticipated duration of transport, temperature control is required and is forbidden by aircraft. 441 For marine pollutants transported under UN3077, Environmentally hazardous substance, solid, n.o.s. or UN3082, Environmentally hazardous substance, liquid, n.o.s. and for purposes of shipping paper and package marking requirements, the technical name used in association with the basic description may be a proper shipping name listed in the 172.101 Hazardous Material Table; provided that the name chosen is not also an entry that includes n.o.s. as a part of the name or one that has a G in column (1) of the table. For all modes of transportation, a written report submitted, retained, and updated in accordance with 171.16 is required if a fire, violent rupture, explosion or dangerous evolution of heat occurs as a direct result of a dry battery or battery-powered device. The letter Z shown in the marking code for composite IBCs must be replaced with a capital code letter designation found in 178.702(a)(2) of this subchapter to specify the material used for the other packaging. The battery has been tested as a primary lithium battery; and. N40 This material is not authorized in the following packagings: a. B44 All parts of valves and safety relief devices in contact with lading must be of a material which will not cause formation of acetylides. Column 1 specifies the T Code. 369 In the case of non-fissile or fissile-excepted uranium hexafluoride, the material must be classified under UN 2978. 144 If transported as a residue in an underground storage tank (UST), as defined in 40 CFR 280.12, that has been cleaned and purged or rendered inert according to the American Petroleum Institute (API) Standard 1604 (IBR, see 171.7 of this subchapter), then the tank and this material are not subject to any other requirements of this subchapter. See also UN1942 in the 172.101 Hazardous Materials Table. 40 Polyester resin kits consist of two components: A base material (either Class 3 or Division 4.1, Packing Group II or III) and an activator (organic peroxide), each separately packed in an inner packaging. (b) Description of codes for special provisions. B30 MC 312, MC 330, MC 331 and DOT 412 cargo tanks and DOT 51 portable tanks must be made of stainless steel, except that steel other than stainless steel may be used in accordance with the provisions of 173.24b(b) of this subchapter. W41 When offered for transportation by water, this material must be packaged in bales and be securely and tightly bound with rope, wire or similar means. Large Packagings are authorized for the Packing Group III entries of specific proper shipping names when either special provision IB3 or IB8 is assigned to that entry in the 172.101 Table. 55 This device must be approved in accordance with 173.56 of this subchapter by the Associate Administrator. W31 Non-bulk packagings must be hermetically sealed. When used for purposes such as sterilization, inner packagings of peroxyacetic acid, stabilized, classified as UN 3107 Organic peroxide type E, liquid or UN 3109 Organic peroxide type F, liquid may be fitted with a vent consisting of hydrophobic membrane, provided: (1) Each inner packaging contains not more than 70 mL; (2) The inner packaging is designed so that the vent is not immersed in liquid in any orientation; (3) Each inner packaging is enclosed in an intermediate rigid plastic packaging with a small opening to permit release of gas and contains a buffer that neutralizes the contents of the inner packaging in the event of leakage; (4) Intermediate packagings are packed in a fiberboard box (4G) outer packaging; (5) Each outer packaging contains not more than 1.4 L of liquid; and. 110 Fire extinguishers transported under UN1044 and oxygen cylinders transported for emergency use under UN1072 may include installed actuating cartridges (cartridges, power device of Division 1.4C or 1.4S), without changing the classification of Division 2.2, provided the aggregate quantity of deflagrating (propellant) explosives does not exceed 3.2 grams per cylinder.
Cory Taylor Cars,
Parque Ridley Creek The Knot,
Easy Knox Gelatin Recipes,
Seminole Police Salary,
Articles C